768 research outputs found

    Testing new-physics models with global comparisons to collider measurements: the Contur toolkit

    Get PDF
    Measurements at particle collider experiments, even if primarily aimed at understanding Standard Model processes, can have a high degree of model independence, and implicitly contain information about potential contributions from physics beyond the Standard Model. The Contur package allows users to benefit from the hundreds of measurements preserved in the Rivet library to test new models against the bank of LHC measurements to date. This method has proven to be very effective in several recent publications from the Contur team, but ultimately, for this approach to be successful, the authors believe that the Contur tool needs to be accessible to the wider high energy physics community. As such, this manual accompanies the first user-facing version: Contur v2. It describes the design choices that have been made, as well as detailing pitfalls and common issues to avoid. The authors hope that with the help of this documentation, external groups will be able to run their own Contur studies, for example when proposing a new model, or pitching a new search

    Bromocriptine treatment associated with recovery from peripartum cardiomyopathy in siblings: two case reports

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Peripartum cardiomyopathy is a rare form of cardiomyopathy, with heterogeneous presentation occurring in women between one-month antepartum and six months postpartum. It carries a poor prognosis and a high risk of mortality.</p> <p>Case presentation</p> <p>We report the development of peripartum cardiomyopathy in two sisters, 27- and 35-year-old African women, one of whom presented with a large left ventricular thrombus. Subsequently, both patients were treated with bromocriptine, heparin and standard therapy for heart failure (angiotensin converting enzyme inhibitors, beta-blockers and diuretics). During follow-up, the left ventricular thrombus observed in one patient degraded. Neither patient experienced a thrombotic event, and both experienced continuous improvements in cardiac function and New York Heart Association stage.</p> <p>Conclusion</p> <p>The development of peripartum cardiomyopathy in two sisters indicates that there may be a genetic basis for this type of cardiomyopathy, and that women with a positive family history for peripartum cardiomyopathy may have an increased risk of developing the disease. This is also the first report of a patient experiencing degradation of a large left ventricular thrombus under standard therapy for heart failure with bromocriptine. It suggests that the use of bromocriptine in association with adequate anti-coagulation and heart failure therapy may be beneficial and safe.</p

    Vasodilation and Exercise Capacity in Patients with End-Stage Renal Disease: A Prospective Proof-of-Concept Study.

    Get PDF
    BACKGROUND Previous data have pointed to the fact that vascular function is significantly impaired in patients with end-stage renal disease (ESRD). We aimed to better characterise vasodilation and exercise capacity in both ESRD and chronic heart failure (CHF) patients. METHODS A total of 30 ESRD patients (23 male; mean age 45.7 ± 9.9 years) were included in a prospective proof-of-concept study at a tertiary care academic centre. The patients underwent forearm venous plethysmography with post-ischaemic peak blood flow (PF) and flow-dependent flow (FDF) testing as well as cardiopulmonary exercise testing during the morning of the day following the last haemodialysis. After matching for age, gender, and body mass index, the data were compared to 30 patients with CHF and 20 age-matched healthy controls. RESULTS PF in ESRD patients was reduced when compared to that in CHF patients (12.5 ± 4.2 vs. 15.6 ± 6.9 ml/100 ml/min; p = 0.048) and healthy controls (26.4 ± 9.3 ml/100 ml/min; p < 0.001). When compared to controls, FDF was significantly reduced in ESRD patients (7.6 ± 3.1 vs. 6.0 ± 2.5 ml/100 ml/min; p = 0.03), but not in CHF patients, whereas resting blood flow did not differ between the ESRD, CHF, and healthy control groups. In contrast to indices of vasodilative capacity, maximum exercise capacity (peakVO2) was higher in ESRD when compared to CHF patients (23.8 ± 7.3 vs. 18.8 ± 5.2 ml/min/kg), but significantly impaired when compared to controls (32.8 ± 6.7 ml/min/kg; p < 0.001). CONCLUSION In this proof-of-concept study, exercise capacity was relatively preserved, while vasodilative capacity was substantially impaired in ESRD patients. Additional studies are warranted to examine the underlying mechanisms and potential clinical implications of our findings

    Reduced functional measure of cardiovascular reserve predicts admission to critical care unit following kidney transplantation

    Get PDF
    Background: There is currently no effective preoperative assessment for patients undergoing kidney transplantation that is able to identify those at high perioperative risk requiring admission to critical care unit (CCU). We sought to determine if functional measures of cardiovascular reserve, in particular the anaerobic threshold (VO2AT) could identify these patients. Methods: Adult patients were assessed within 4 weeks prior to kidney transplantation in a University hospital with a 37-bed CCU, between April 2010 and June 2012. Cardiopulmonary exercise testing (CPET), echocardiography and arterial applanation tonometry were performed. Results: There were 70 participants (age 41.7614.5 years, 60% male, 91.4% living donor kidney recipients, 23.4% were desensitized). 14 patients (20%) required escalation of care from the ward to CCU following transplantation. Reduced anaerobic threshold (VO2AT) was the most significant predictor, independently (OR = 0.43; 95% CI 0.27–0.68; p,0.001) and in the multivariate logistic regression analysis (adjusted OR = 0.26; 95% CI 0.12–0.59; p = 0.001). The area under the receiveroperating- characteristic curve was 0.93, based on a risk prediction model that incorporated VO2AT, body mass index and desensitization status. Neither echocardiographic nor measures of aortic compliance were significantly associated with CCU admission. Conclusions: To our knowledge, this is the first prospective observational study to demonstrate the usefulness of CPET as a preoperative risk stratification tool for patients undergoing kidney transplantation. The study suggests that VO2AT has the potential to predict perioperative morbidity in kidney transplant recipients

    Static and Dynamic Lung Volumes in Swimmers and Their Ventilatory Response to Maximal Exercise

    Get PDF
    Purpose While the static and dynamic lung volumes of active swimmers is often greater than the predicted volume of similarly active non-swimmers, little is known if their ventilatory response to exercise is also different. Methods Three groups of anthropometrically matched male adults were recruited, daily active swimmers (n = 15), daily active in fields sport (Rugby and Football) (n = 15), and recreationally active (n = 15). Forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and maximal voluntary ventilation (MVV) was measured before and after exercise to volitional exhaustion. Results Swimmers had significantly larger FVC (6.2 ± 0.6 l, 109 ± 9% pred) than the other groups (5.6 ± 0.5 l, 106 ± 13% pred, 5.5 ± 0.8, 99% pred, the sportsmen and recreational groups, respectively). FEV1 and MVV were not different. While at peak exercise, all groups reached their ventilatory reserve (around 20%), the swimmers had a greater minute ventilation rate than the recreational group (146 ± 19 vs 120 ± 87 l/min), delivering this volume by breathing deeper and slower. Conclusions The swimmers utilised their larger static volumes (FVC) differently during exercise by meeting their ventilation volume through long and deep breaths

    Influence of the incremental step size in work rate on exercise response and gas exchange in patients with pulmonary hypertension

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiopulmonary exercise testing (CPET) has become increasingly important as a routine procedure in daily clinical work. So far, it is generally accepted that an individualized exercise protocol with exercise duration of 6 to 12 minutes is preferable to assess maximal exercise performance. The aim of this study was to compare an individualized NYHA adapted exercise protocol with a fixed standard protocol in patients with severe pulmonary arterial hypertension.</p> <p>Methods</p> <p>Twenty-two patients (17 female, 5 male; mean age 49 ± 14 yrs) underwent symptom limited CPET on a bicycle. On two consecutive days each subject performed a stepwise CPET according to a modified Jones protocol (16 Watt per minute stages) as well as an individualized NYHA adapted protocol with 5 or 10 Watt/min stages in a randomized order. Oxygen uptake at peak exercise (peakVO<sub>2</sub>) and anaerobic threshold (VO<sub>2</sub>AT), maximal ventilation (VE), breathing reserve (VE/MVV), ventilatory efficiency (VE vs. VCO<sub>2 </sub>slope), exercise time, maximal power and work rate were assessed and compared between both protocols.</p> <p>Results</p> <p>Comparing both, adapted NYHA protocol and standardized Jones protocol, we found significant differences in maximal power (56.7 ± 19 W vs. 74 ± 18 W; p < 0.001) and exercise time (332 ± 107 sec. vs. 248 ± 72 sec.; p < 0.001). In contrast, no significant differences were obvious comparing both protocols concerning work rate, VE, VE/MVV, peakVO<sub>2</sub>, VO<sub>2</sub>AT and VE vs. VCO<sub>2 </sub>slope.</p> <p>Conclusion</p> <p>Variations of incremental step size during CPET significantly affect exercise time and maximal power, whereas relevant parameters for clinical judgement and prognosis such as oxygen uptake, ventilation and ventilatory efficiency remain unchanged. These findings have practical implications for the exercise evaluation of patients with pulmonary hypertension. To reach maximal results for ventilation, oxygen uptake and gas exchange an individualization of incremental step size appears not to be mandatory.</p

    Search for resonant WZ production in the fully leptonic final state in proton–proton collisions at √s=13 TeV with the ATLAS detector

    Get PDF

    Measurement of exclusive pion pair production in proton–proton collisions at √s=7 TeV with the ATLAS detector

    Get PDF

    Measurement of the energy asymmetry in tt¯ j production at 13 TeV with the ATLAS experiment and interpretation in the SMEFT framework

    Get PDF
    A measurement of the energy asymmetry in jet-associated top-quark pair production is presented using 139fb-1 of data collected by the ATLAS detector at the Large Hadron Collider during pp collisions at s=13TeV. The observable measures the different probability of top and antitop quarks to have the higher energy as a function of the jet scattering angle with respect to the beam axis. The energy asymmetry is measured in the semileptonic tt¯ decay channel, and the hadronically decaying top quark must have transverse momentum above 350GeV. The results are corrected for detector effects to particle level in three bins of the scattering angle of the associated jet. The measurement agrees with the SM prediction at next-to-leading-order accuracy in quantum chromodynamics in all three bins. In the bin with the largest expected asymmetry, where the jet is emitted perpendicular to the beam, the energy asymmetry is measured to be - 0.043 ± 0.020 , in agreement with the SM prediction of - 0.037 ± 0.003. Interpreting this result in the framework of the Standard Model effective field theory (SMEFT), it is shown that the energy asymmetry is sensitive to the top-quark chirality in four-quark operators and is therefore a valuable new observable in global SMEFT fits
    corecore